Zum Hauptinhalt springen Zur Suche springen Zur Hauptnavigation springen
Haben Sie Fragen? Einfach anrufen, wir helfen gerne: Tel. 089/210233-0
oder besuchen Sie unser Ladengeschäft in der Pacellistraße 5 (Maxburg) 80333 München
+++ Versandkostenfreie Lieferung innerhalb Deutschlands
Haben Sie Fragen? Tel. 089/210233-0

On Physiological Closed-Loop Control for Lung-Protective Mechanical Ventilation

59,80 €*

Versandkostenfrei

Produktnummer: 1875a21470634347868b23d6e4f14e27ce
Autor: von Platen, Philip
Themengebiete: Closed-Loop Control Hysteresis Modelling Mechanical Ventilation Physiological Modelling Robust Control
Veröffentlichungsdatum: 23.09.2024
EAN: 9783844096583
Auflage: 1
Sprache: Englisch
Seitenzahl: 210
Produktart: Kartoniert / Broschiert
Verlag: Shaker
Produktinformationen "On Physiological Closed-Loop Control for Lung-Protective Mechanical Ventilation"
Mechanical ventilation remains a cornerstone in the treatment of patients with respiratory failure. However, careful, constant, and lung-protective adjustment of ventilator settings is required to prevent ventilator-induced lung injury. This work presents contributions to the field of physiological closed-loop control, which has the potential to achieve continuous lung-protective mechanical ventilation and reduce clinician workload. First, the large signal behaviour of the respiratory system is studied, including the non-linear hysteretic phenomenon that significantly affects the operating points of tidal ventilation. A mathematical Preisach hysteresis model of the respiratory system is derived, accurately replicating clinically measured pressure-volume curves and serving as a foundation for the automation of lung recruitment manoeuvres. Next, the model-based design of robust closed-loop controllers for precise control of systemic oxygenation is described. Extensive simulations and results from animal experiments demonstrate the controllers' accuracy, reliability, and safety despite significant uncertainties in the process. Finally, a complete physiological closed-loop system capable of automatically adjusting all ventilator settings is presented. Results from animal trials demonstrate that the system can maintain subjects within defined targets while adhering to lung-protective guidelines and requiring minimal clinician interaction.
Bücherregal gefüllt mit juristischen Werken

Sie möchten lieber vor Ort einkaufen?

Sie haben Fragen zu diesem oder anderen Produkten oder möchten einfach gerne analog im Laden stöbern? Wir sind gerne für Sie da und beraten Sie auch telefonisch.

Juristische Fachbuchhandlung
Georg Blendl

Parcellistraße 5 (Maxburg)
8033 München

Montag - Freitag: 8:15 -18 Uhr
Samstags geschlossen